摘要
分析了一台冷凝器发生液泛的原因 ,其主要原因是由于该冷凝器与其下面的贮槽相对高度不足所致。计算结果与实际情况基本吻合。
The reasons of liquid flood occurring in a condenser are analyzed. The main cause involves the less relative height between the condenser and the storing bank under it. The calculating results are basically fitted to the practical situations. It provides a calculating method and foundations to vacuum operating chemical engineering design as well as process.
出处
《辽宁工学院学报》
2001年第3期42-43,共2页
Journal of Liaoning Institute of Technology(Natural Science Edition)