高层建筑消防给水设计的体会

Experience with fire water-supply design of high buildings
下载PDF
导出
摘要 根据工作经验 ,就高层建筑消防给水设计中供水方式的选择 ,消防水泵的超压 ,综合性建筑消防水量的确定等问题 ,提出了解决方法 :自动喷水系统和消火栓系统各设消防泵 ,确保了消防水量和供水时间 ;采用多台水泵分层控制 ,安全阀泄压等措施 ,解决了水泵的超压问题 ;根据楼房的主要用途来考虑综合性建筑的消防水量 。 According to working experience with fire water?su pply design of high buildings, the paper puts forward solving ways for selection of water?supply wa y , overpressure of fire water pump and determination of fire water yield of synth etic building: fire pumps of automatic spraying water system and fire cock syste m ensure fire water yield and supplying time, many pumps of controlling by layer and decompression by safety valve solve problem of overpressure of pump, fire w ater yield of synthetic building is considered by use of buildings, and these ma ke design of fire system safe and reliable.
作者 李玉娟
出处 《山西建筑》 2001年第2期124-125,共2页 Shanxi Architecture
关键词 消火栓 自动喷水系统 小水枪 高层建筑 消防给水 fire cock system, automatic spraying water system, overpressure, small water gun