期刊文献+

分光光度法测定溶液的化学需氧量 被引量:7

Spectrophotometric Method for the Determination of COD
下载PDF
导出
摘要 采用自行研制的消化液配合美国HACH公司的MD4 5 60 0型COD反应仪及DR/ 2 0 10型分光光度计测定溶液的化学需氧量 (COD) .在 2 .0 0mL分析水样中加入一定量自行研制的消化液和催化剂 ,消化反应一定时间后 ,直接通过比色法用分光光度计测定COD ,操作简便 ,检测速度快 ,测量费用低 ,准确度和精密度均相当高 ,其相对标准偏差RSD =1.78% ,完全可以与美国HACH公司提供的标准试剂法相媲美 . This paper introduces a simple and practical method to determine COD, which is easy to operate, convenient and economical. Cooperating with HACH MD45600 COD reactor, digestion to solution and catalyst prepared with routine reagents are used to oxide the sample (only 2.00 mL) and HACH DR/2010 spectrophotometer to determine COD Cr . The accuracy and the reappearance ability of the method accord with the monitoring requirements RSD=1.78%, which is as good as the one obtained from the standard solvent method advanced by HACH method Co.
作者 范娟 阮复昌
出处 《华南理工大学学报(自然科学版)》 EI CAS CSCD 北大核心 2001年第7期95-98,共4页 Journal of South China University of Technology(Natural Science Edition)
基金 广东省自然科学基金资助项目 (96 0 2 19)
关键词 化学需氧量 分光光度计 半微量法 水处理 氧化剂 消化液 催化剂 COD spectrophotometer semi_macro method
  • 相关文献

参考文献5

  • 1国家环保局《水和废水监测分析方法》编委会.水和废水监测分析方法(第3版)[M].北京:中国环境科学出版社,1997.354-356.
  • 2国家环保局《水和废水监测分析方法指南》编委会.水和废水监测分析方法指南(中册)[M].北京:中国环境科学出版社,1997.306-316.
  • 3阮复昌,李向明,莫炳禄,范娟,公国庆,卢燕玲.一种新的五日生物需氧量分析方法[J].分析测试学报,1997,16(5):14-17. 被引量:3
  • 4国家环保局《水和废水监测分析方法》编委会,水和废水监测分析方法(第3版),1997年,354页
  • 5国家环保局《水和废水监测分析方法》编委会,水和废水监测分析方法指南.中,1997年,306页

二级参考文献8

共引文献8

同被引文献54

引证文献7

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部