摘要
结合电厂几年运行经验 ,分析了在联合循环运行时向燃气轮机燃烧室注水及不注水情况下对燃烧室热部件耐热瓦及后循环的影响 ,阐述在联合循环运行时向燃气轮机燃烧室注水及不注水情况下优缺点。
On the basis of the operating experience of a power plant over the years an analysis was conducted of the influence of water injection or no water injection on the heat resistant pad of combustor components as well as on the components of a post-cycle. The water injection has been applied to the combustor of a gas turbine operating under combined cycle power plant conditions. In this context, expounded are the merits and demerits of employing water injection or no injection into the combustor of the above-mentioned gas turbine.
出处
《热能动力工程》
EI
CAS
CSCD
北大核心
2001年第3期331-333,共3页
Journal of Engineering for Thermal Energy and Power
关键词
燃气轮机
燃烧室
联合循环
耐热瓦
注水系统
gas turbine, combustor, combined cycle power plant, heat resistant pad