期刊文献+

底部框架-抗震墙砖房框剪层抗震墙数量的合理确定 被引量:5

A REASONABLE AND SIMPLE DETERMINING METHOD OF ASEISMIC WALL NUMBERS IN FRAME-SHEAR WALL STORIES OF MASONRY BUILDING WITH FRAME STRUCTRUE AT LOWER STORIES
下载PDF
导出
摘要 根据已有研究成果提出的砖混过渡层与相邻框剪层的侧移刚度比限值及《建筑抗震设计规范》(GB5 0 0 11)规定的楼层侧移刚度比、层间弹性和弹塑性位移、抗震墙最小厚度、抗震横墙最大间距等限值 ,探讨了底部框架砖房框剪层抗震墙的合理数量范围 ,并从实用出发 ,提出了抗震墙数量可采用两重或三重约束的简化方法确定。 Based on the limit value of horizontal stiffness ratio of first brick masonry story to next frame shear story,interstorey displacement,minimum thickness of aseismic wall,maximum distance of aseismic cross wall and so on,which are provided by some documents and the “Building Aseismic Design Code”(GB50011),a reasonable and simple determining method of aseismic wall numbers for frame shear stories of masonry building with frame structure at lower stories is presented.
作者 郑山锁
出处 《工业建筑》 CSCD 北大核心 2001年第5期22-25,共4页 Industrial Construction
关键词 砖结构 抗震墙 框架 层间位移 侧移刚度比 masonry building with frame structure at lower stories horizontal stiffness ratio interstorey displacement aseismic wall numbers
  • 相关文献

参考文献2

  • 1郑山锁.底部框架-抗震墙砖房抗震性能及设计方法的研究(博士学位论文)[M].西安:西安建筑科技大学,2000,6..
  • 2郑山锁,博士论文,2000年