两级氯化钙化学沉淀法处理电冰箱、洗衣机生产含磷废水 被引量:2

Treatment of Phosphorus Wastewater from Household Refrigerator and Washer Factory by Two-Step Precipitation Using Calcium Chloride
下载PDF
导出
摘要 介绍了两级氯化钙化学沉淀法处理家电生产前处理工序含磷废水的工程实践。结果表明 ,在进水磷酸盐 (以P计 )为 10~ 50mg/L时 ,分别控制钙磷化学计量比为 2∶1、5∶1,pH为 10 0~10 5、10 5~ 11 0 ,经过两级化学沉淀处理 ,出水磷酸盐 (以P计 )为 0 174~ 0 189mg/L。 Engineering practice of two step chemical precipitation using calcium chloride to treat the wastewater contained phosphorus from household refrigerator and washer factory is introduced. When the inlet phosphate content is in range of 10~50mg/L (as P), under condition that the Ca/P ratio is 2∶1, 5∶1 and pH is 10.0~10.5, 10.5~11.0 respectively, the phosphate content in effluent of the chemical precipitation process will be as low as 0.174~0.189mg/L.
出处 《给水排水》 CSCD 北大核心 2001年第6期45-47,共3页 Water & Wastewater Engineering
  • 相关文献

参考文献3

共引文献18

同被引文献23

  • 1李长江,郭一令,任晓伟.混凝沉淀+砂滤处理高浓度含磷废水[J].西南给排水,2005,27(4):26-27. 被引量:6
  • 2VARGAS M,CASAS C,BAEZA J A.Maintenance of phosphorus removal in an EBPR system under permanent aerobic conditions using propionate[J].Biochem Eng J,2009,43(3):288-296.
  • 3AHN J,SCHROEDER S,BEER M,et al.Ecology of the microbial community removing phosphate from wastewater under continuously aerobic conditions in a sequencing batch reactor[J].Appl Environ Microbiol,2007,73(7):2257-2270.
  • 4IRDEMEZ S,YILDIZ Y S,TOSUNO LU V.Optimization of phosphate removal from wastewater by electrocoagulation with aluminum plate electrodes[J].Sep Purif Technol,2006,52(2):394-401.
  • 5IRDEMEZ S,DEMIRCIO LU N,YILDIZ Y S.The effects of p H on phosphate removal from wastewater by electrocoagulation with iron plate electrodes[J].J Hazard Mater,2006,137(2):1231-1235.
  • 6LIU R X,GUO J L,TANG H X.Adsorption of fluoride,phosphate,and arsenate ions on a new type of ion exchange fiber[J].J Colloid Interf Sci,2002,248(2):268-274.
  • 7AWUAL M R,JYO A.Assessing of phosphorus removal by polymeric anion exchangers[J].Desalination,2011,281:111-117.
  • 8AWUAL M R,JYO A,El-SAFTY S A,et al.A weak-base fibrous anion exchanger effective for rapid phosphate removal from water[J].J Hazard Mater,2011,188(1/2/3):164-171.
  • 9中华人民共和国环境保护部.GB11893—89水质总磷的测定:钼酸铵分光光度法[S].北京:中国标准出版社,1990.
  • 10赵颖,王军,王琪,栾兆坤,梁震.赤泥吸附去除淀粉废水中高浓度磷的研究[J].中国给水排水,2009,25(3):20-22. 被引量:16