摘要
研究不同频率慢性电刺激(CES)后兔膈肌肌浆网(SR)Ca2+-ATPase活性以及SR Ca2+摄取-释放动力学对不同频率CES的适应性变化。建立不同频率CES组;用定磷法测定SR Ca2+-ATPase活性;用Fura-2荧光法测定SR Ca2+摄取-释放动力学。与对照组比较,慢性低频电刺激10 Hz和20Hz组的SR Ca2+-ATPase活性明显降低(P<0.01),Ca2+释放-摄取动力学也显著降低(P<0.01);慢性高频电刺激50 Hz和100Hz组的SR Ca2+-ATPase活性则显著升高(P<0.01),Ca2+释放-摄取动力学亦明显升高(P<0.01)。实验提示,CES后不同频率CES导致膈肌SRCa2+-ATPase、Ca2+摄取-释放动力学产生不同的适应性变化;对不同功能状态的膈肌应用不同频谱的慢性电刺激可能具有重要的临床意义。
To study adaptation of rabbit diaphragm muscle after different-frequency chronic electrical stimu-lation, Ca2+ -ATPase activity and Ca2+ release-uptake kinetics of sarcoplasmic reticulum (SR) were respec-tively measured by detecting inorganic phosphorus ion and Furo-2 fluorescence. SR Ca2+ -ATPase activity of the low-frequency stimulation group was significantly lower than that of the control group (P <0.01), but it was significantly higher in the high-frequency stimulation group against control (P <0.01). The kinetics of Ca2+ release and Ca2+ uptake was significantly lower in low-frequency group than that of the control (P < 0.01), but the kinetics of Ca2+ release and Ca2+uptake was significantly higher than that of the control (P < 0.01). It is thought that different frequency electrical stimulation induced different adaptative changes in SR Ca2+ -ATPase activity, and Ca2+ release and uptake kinetics of rabbit diaphragm muscle.
出处
《生理学报》
CAS
CSCD
北大核心
2001年第3期219-223,共5页
Acta Physiologica Sinica
基金
This work was supported by the National Natural Science Foundation of China (No.39470325).