期刊文献+

采用带微型预处理柱和分离柱的FIA分光光度系统同时测定硅和磷

Simultaneous determination of silica and phosphate in biological and plant materials by using HPLC colums based on flow injection spectrophotometry
下载PDF
导出
摘要 用阳阴离子交换柱和流动注射分析组合 ,建立了在线预处理和预分离同时测定磷和硅的 FIA方法。用本法测定了头发、淡菜、茶叶、马尾藻和大米中的硅和磷。方法的测定范围为 1 .0 mg/ L~ 2 4 mg/ L ( PO4 3 -) ,0 .5mg/ L~ 1 2mg/ L( Si O3 2 -) ,回收率 :96.7%~ 99.0 % ( PO4 3 -) ,1 0 0 %~ 1 0 2 % ( Si O3 2 -) ;RSD( PO4 3 -) =1 .3% ,RSD( Si O3 2 -) =1 .8%。 A description of simultaneously determining silicate and phosphate in human hair, mussel,tea leaves,sargasso and rice flour is given by using a flow injection spectrophtometric system based on an on line ion exchange pretreatment to remove interfering cations and a separation column to separate silicate and phosphate ions in the sample zone.The determination ranges are 1 0 mg/L~24 mg/L for PO 4 3- and 0 5 mg/L~12 mg/L for SiO 3 2- . Recovery ranges are 96.7%~99 0% for PO 4 3- and 100%~102% for SiO 3 2- with RSD of 1.3% and 1.8%,respectively.
出处 《分析试验室》 CAS CSCD 北大核心 2001年第4期53-57,共5页 Chinese Journal of Analysis Laboratory
关键词 同时测定 FIA 在线预处理 在线分离 离子交换柱 流动注射 分光光度法 Flow injection analysis Silicate phosphate Cation exchange Anion exchange
  • 相关文献