期刊文献+

直接电位法测定工业废水中的硫氰酸根离子 被引量:11

Determination of thiocyanate anion in waste water of industories by direct potential method using thiocyanate anion selective electrode
下载PDF
导出
摘要 用直接电位法测定了统扑净生产废水和印染厂排放废水中硫氰酸根的浓度。在温度为 1 6℃ ,浓度为 0 .0 2 mol/L HCl的体系中 ,以功能高分子 PVC-双硫腙 -铜 ( I)载体的 SCN-离子电极在 SCN-离子浓度为 1 .0× 1 0 -2 ~ 5× 1 0 -6mol/L时呈能斯特响应 ,斜率为 58± 2 m V/dec,检出限为 2 .0× 1 0 -6mol/L。电极的选择性次序为 :SCN->>Cl O4 -~Sal->>Cl->NO3 ->HPO4 2 ->SO4 PVC diphenylthiocabazone Cu(Ⅰ) liquid membrane anion selective electrodes were used to determine SCN -.The Nerstian response of the electrodes was from 10 -2 to 5.0×10 -6 mol/L for thiocyanate with the slope of 58±2 mV/dec (16℃) in 0 02 mol/L hydrochloride acid solution. The detection limit was 2×10 -6 mol/L . The selectivity sequence observed is:SCN ->>ClO 4 -~Sal ->> Cl - >NO 3 - >HPO 4 2- >SO 4 2- .The method was applied to determination of SCN - in waste water with satisfactory results.
出处 《分析试验室》 CAS CSCD 北大核心 2001年第3期66-68,共3页 Chinese Journal of Analysis Laboratory
基金 湖南省教育厅科学基金资助课题 !(0 0 C0 2 3 )
关键词 硫氰酸根 工业废水 液态膜离子选择电极 直接电位法 环境监测 分析方法 Thiocyanate Waste water Liquid membrane ion selective electrode Direct potetial method
  • 相关文献

参考文献3

二级参考文献11

  • 1刘冬 沈国励 等.-[J].高等学校化学学报,1996,17:1528-1528.
  • 2Li Zhiqiang,Talanta,1998年,46卷,943页
  • 3Li Zhiqiang,Anal Lett,1997年,30卷,1455页
  • 4刘冬,高等学校化学学报,1996年,17卷,1528页
  • 5李志强,高等学校化学学报,1999年,20卷,47页
  • 6Li Z Q,Talanta,1998年,46卷,943页
  • 7Li Z Q,Anal Lett,1997年,30卷,1455页
  • 8沈含熙,分析化学,1995年,23卷,894页
  • 9Yuan R,分析化学,1993年,65卷,2572页
  • 10周名成,紫外与可见分光光度法分析,1986年,209页