摘要 目的 改善射线数字成像系统的图像质量 .方法 在射线数字成像系统中 ,存在许多影响图像质量的因素 ,这些因素来源于系统的各个成像环节 ,如 CCD相机、成像屏、X射线源、被测物体、控制电路、射线散射等 ,它们对成像质量造成严重影响 .作者针对 DR成像系统降低图像质量的因素作了分析 ,并通过校正和图像处理的方法使其得到了抑制 .结果 提出了改善射线数字成像系统图像质量的方法 .结论 通过实际应用 ,表明所提出的方法是有效的 . Aim\ To improve the image quality in digital r adiographic(DR) system. Methods\ In DR system there are many degrading factors of DR image , which originate from most of elements of the system, such as CCD camera, image eonversion screen, x-ray source, inspected object, controlling circuits, X-ra y scattering and etc. They influence on image quality seriously. Aimed at the p erformance of the degrading factors in DR system, these factors are analyzed and suppressed by correction and image processing. Results\ The methods of improvement of image quality are presented . Conclusion\ It is shown that the presented methods are effective through practical application.
作者 陈树越
出处 《测试技术学报》 2001年第3期163-168,共6页 Journal of Test and Measurement Technology
关键词 数字射线成像系统 无损检测 图像校正 图像质量 digital radiography image correction signal noise charge couple device
  • 相关文献

参考文献5

  • 1[1]Halmshaw 4.Industrial Radiography. 2nd edition, Chapman&Hall, 1995. 267.
  • 2[2]Burch S. Digital enhancement of video images for NDT. NDT International, 1987,20(1): 51~56.
  • 3[3]Throup D. Improving images from real time radioscopic sources, X-ray Real-Time Radiography and Image Processing, R., Halmshaw, Ed., Sym. British Inst. NDT Newbury, Berkshire, 1988. 87~95.
  • 4[4]Pratt W K. Digital Image Processing, John Wiley & Sons, Inc., 1978. 307~342.
  • 5[5]Chen, Shuyue. Study on the improvement of X-ray digital radiography quality, Ph.D. Dissertation, Nanjing University of Sci. and Tech., 2001.