摘要
元宝山电厂2号炉自投运以来,一直不能带满负荷运行,东北电力试验研究院分析了锅炉特性,进行了分级送风、低氧燃烧的试验研究工作。文中分析了欠氧燃烧原理及运行特性,并对其正、负两方面的影响进行了探讨。经技术改造,该机组运行负荷已达600MW,锅炉实现了满负荷连续稳定运行。
No.2 boiler in Yuanbaoshan Power Plant could not operate at full load ever since it went into operation.Northeast Power Testing and Research Institute analyzed the boiler characteristics,conducted testing and research works on stage forced draft,low oxygen combustion,analyzed the principle of under oxidized combustion and operation characteristics,and explored its both positive and negative impacts.Through retrofitting,No.2 generating unit has been able to operate up to 600 MW,realizing full load continuous stable operation.
出处
《中国电力》
CSCD
北大核心
1998年第9期3-7,共5页
Electric Power
关键词
电厂
600MW机组
锅炉
分级燃烧
试验
boiler stage combustion slagging cha ra cteristics combustion adjustment