以结合实例的方式探讨了大型电力用户10kV高压电房的二次典型设计方案,提出了应参照广州地区110kV城区变电站的典型模式,按一座“10kV二级变电站”的形式来规范设计和管理。
The secondary system modular design for 10 kV HV switch-houses of heavy loads is discussed with examples. It is suggested that the design and management should be standardized in the form of aa10kV secondary substation' with reference to the modular design of 110 kV urban substations in Guangzhou.
出处
《广东电力》
1998年第3期26-28,共3页
Guangdong Electric Power
关键词
变电站
高压电房
二次系统
设计
电力用户
power consumption
consumer
switching house
secondary system
modular design
discussion