摘要
通过理论分析、数值仿真 ,详细介绍了晶闸管相控电抗器特征谐波的产生机理和采用变压器移相消除谐波的方法。
This paper analyses characteristic harmonic currents of TCR and presents a method to reduce the harmonics by means of phase shift transformer.A simulation is carried out and the results are presented in this paper as well.