低旋设计散光软镜临床配戴结果研究 被引量:3

A clinical study of Lo-torque designed toric soft contact lens
下载PDF
导出
摘要 目的 :评估低旋 (Lo Torque)设计散光软镜的临床效果。方法 :10 3名近视散光自愿者分别配戴A、B镜片各两周。对配戴的临床表现进行客观和主觉评价 ,采用双盲法。结果 :①镜片稳定性 :A镜片旋转范围≤5°为 82 % ,B镜片为 5 2 %。②镜片在眼中状态 :移动度优良者 ,A镜片为 91% ,B镜片为 95 % ;中心定位优良者 ,A镜片为 87% ,B镜片为 77%。③舒适度评价 :A镜片优良者为 85 .5 % ,B镜片为 80 .2 %。结论 :低旋设计特征的散光软镜更符合人眼的生理特征 ,可以提高视觉质量 ,增加配戴舒适度。 Objective:To evaluate the impact of the Lo Torque designed soft toric lenses on the performance of clinical fitting.Methods:103 myopias with astigmatism fitted the A and B lens respectively for 2 weeks, and the evaluation included the subjective and objective examination. The fitting and evaluation is double masked.Results:① Lens stability:A lens rotation≤5° takes 82%,B lens takes 52%.②lens performance:excellence in movement with A lens is 91%,B lens is 95%;excellence in centration with A lens is 87%,B lens is 77%.③confort:excellent with A lens is 85.5%,B lens is 80.2%.Conclusion:Lo Torique designed soft toric lens is improved better fitting for the toric subjects with better visual acuity and more comfort.
作者 赵燕杰
出处 《眼视光学杂志》 2001年第2期111-112,共2页 Chinese Journal of Optometry & Ophthalmology
关键词 Lo-Torque设计 散光软镜 镜片稳定性 Lo Torque design soft toric lens stability
  • 引文网络
  • 相关文献

参考文献2

  • 1[1]Cox I,Comstock T,Reindel W. A clinical comparison of two soft troic contact lenses[J]. Optician,1999,218(3):32-34.
  • 2[2]Hickson-Curran S,Veys J,Dalton L. A new dual-thin zone disosable toric lens[J]. Optician,2000,219(4):18-26.

同被引文献30

  • 1谢培英.角膜接触镜[M].北京:人民卫生出版社,1998.38-56.
  • 2Holden BA. The Principles and practice of correcting astigmatism with soft contact lenses[J ]. Aust J Optom, 1975,58: 279-299.
  • 3Harold AS, Bernard JS, Raymond MS. Fitting Guide for Rigid and Soft Contact Lenses:A Practical Approach [ M ]. 4th ed. The United States: Mosby, 2002,323-336.
  • 4Baron WS. Cyclorotation impacts on toric contact lens fitting and performance[ J ]. Optom Vis Sci, 1994,71: 350-352.
  • 5Tomlinson A, Bibby MM. Lid interaction and toric soft lens axis location[J ]. Am J Optom Physiol Opt, 1982,59:228-233.
  • 6Efron N, Brennan NA, Currie JM, et al. Determinants of the initial comfort of hydrogel contact lenses[J]. Am J Optom Physiol Opt,1986,63 : 819-823.
  • 7McMonnies CW. The critical initial comfort of soft contact lenses [J ]. Clin Exp Optom, 1997,80: 53-58.
  • 8Waldron HE. Influence of the lids on contact lens location and orientation[J]. Am J Optom Physiol Opt, 1984,61:129-132.
  • 9Snyder C, Talley DK. Masking of astigmatism with selected soft contact lens[J ]. J Am Optom Associ, 1989,60: 728-731.
  • 10Holden BA. Correcting astigmatism with toric soft contact lenses-an overview[J ]. Int Cont Lens Clin, 1976,3: 59-61.

引证文献3

二级引证文献4

;
使用帮助 返回顶部