摘要
本文介绍TX4280型坐标镗床感应同步器数显测量系统的“双行程开关单动”误差补偿装置的工作原理、调整方法、补偿效果以及该系统的可靠性、抗干扰性的性能试验与试验结果.
This paper introduces the principle, adjusting method and results of the error-compensating gear for single action with double stroke keys, used in the induction synchronizer digital display measurement system of TX4280 coordinate borer. It also deals with the reliability and the anti-interference experiment, and shows the experimental results.
关键词
坐标镗床
数显测量系统
误差补偿
coordinate borer, induction synchronizer measurement system, error compensating gear.