摘要
针对静态容积法水流量标准装置流量一致性问题,本文提出一种等面积补偿法,可有效提高水表检定的重复精度,保证流量稳定度不低于0.2%。
In connection with the problem of identity encountered in the measurement of accumulative water flow by the standard water meter constructed according to the static volume method, an equi-area compensation method is proposed. The new method may improve the reproducibility of measurement in water meter inspection, and the steadiness of water flow can be ensured to no lower than 0.2%.