对计算电子管高私功放级所用的“东芝”图表法进行了证明,指出了这是一种融合了折线法和图解法两种优点的方法.通过一个实例,对计算方法作了较详尽的分析.
This article gives a proof of the TOSHIBA graphic solution to the high frequency tube amplifier. The paper stresses that this method has the advantages of both broken-line method and graphic method. And a detailed analysis of the method is shown through a pratical example.