期刊文献+

CCD在弹丸消融观测中的应用 被引量:1

CCD application on observation of pellet ablation
下载PDF
导出
摘要 描述 CCD器件在 HL-1 M多发弹丸加料实验中观测短暂消融云的应用结果 ,并介绍一种有特色的触发方式用弹丸自身辐射的氢α射线启动相机。实验证明 :这种安排能取得大量照片 ,CCD成功地应用于弹丸消融过程观测 ,图片处理分析后获得消融云形状、结构和辐射强度分布等。可以相信 CCD诊断方法不但加深了弹丸加料的认识 。 This paper describes the observed results of short-time pellet ablation based on CCD application during the multi-pellet fuelling experiment in the HL-1M tokamak, introduces a characteristic trigger mode, that is, Hα radiation signal emitting from pellet itself to trigger CCD camera. The experiment proves that a lot of photos can be taken through this arrangement and CCD camera is successfully applied to pellet ablation process investigation. Through photos processing and analysis, the structure on different plasma positions, dimension and space emission profile of ablation cloud are obtained, therefore the CCD diagnosis means not only makes pellet fuelling understand deeply, but also may promote the transient and high-speed process research in the field of military and engineering.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2001年第4期403-407,共5页 High Power Laser and Particle Beams
基金 国际原子能机构 IAEA CRP/4/0 13 -0 2资助课题
关键词 CCD Hα触发 弹丸消融 观测 应用 弹丸注入 稳态聚变堆 等离子体 Ablation Cameras Plasmas Radiation Tokamak devices
  • 相关文献

参考文献3

二级参考文献6

  • 1杨进蔚,张光阳,张炜,曾庆希,李正辉,李伟堂.碘化汞探测器及其对HL-1M装置中X射线辐射测量[J].核电子学与探测技术,1997,17(2):103-107. 被引量:3
  • 2洪文玉 王恩耀 等.HL-1M装置边缘扰动和流速的实验研究[J].真空科学技术,1998,18(3):176-176.
  • 3洪文玉,真空科学与技术学报,1998年,18卷,3期,176页
  • 4Chang C T,Phys Reports,1991年,206卷,4期,143页
  • 5Chang C T,Phys Reports,1991年,206卷,4期,145页
  • 6肖正贵,刘德权,李波,李立,董贾福,邓中朝,郭干城,洪文玉.HL-1M装置多发弹丸加料实验观测[J].核聚变与等离子体物理,1999,19(1):21-26. 被引量:9

共引文献11

同被引文献4

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部