摘要 目的 研究符合电路SPECT心肌灌注/代谢显像诊断冠心病的临床价值。方法 28例冠心病患者,男26例,女2例,分别行心肌血流灌注和心肌代谢显像,全部28例均行冠状动脉造影,25例行心电图运动平板试验。结果 以冠脉造影为金标准,心肌灌注显像、心肌灌注/代谢显像和心电图运动平板试验诊断冠心病的准确率分别为82.14%,89.28%和72%(P<0.05和P<001)。结论 符合电路SPECT心肌灌注/代谢显像,在冠心病的诊断中具有一定的应用价值,且优于静息心肌血流灌注显像和心电图运动平板。 Purpose To investigate the clinical value of using myocardial perfusion/metabolism MCD SPECT in diagnosing coronary artery disease(CAD) .Methods There were 28 patients with CAD(26 males and 2 females) who got myocardial perfusion/melabolism imaging. Coronary angiography was performed in all of these patients and exercise electrocardiogram test was performed in 25 of them. Results The diagnostic accuracy of CAD were 82.14% ,89.28% and 72% respectively for perfusion SPECT,perfusion/metabolism imaging and exercise electrocardiogram test.Conclusions Myocardial perfusion/metabolism MCD SPECT is useful in diagnosing CAD and is superior to test myocardial perfusion imaging or exercise electrocardiogram test.
出处 《上海医学影像》 2001年第2期98-100,共3页 Shanghai Medical Imaging
关键词 符合电路SPECT 冠心病 ^18氟-脱氧葡萄糖 ^99M锝-甲氧基异丁基异腈 心肌灌注显像 Coincidence detection Coronary artery disease Fluorine - 18 - fluorodoxyglucose(^(18) F - FDG) To - 99m MIBI(^(99m)Tc- MIBI)
  • 相关文献

参考文献7

  • 1[1]Sandler MP, Bax JJ, Patton JA, et al. Fluorine-18-fluorodeoxyglu cose cardiac imaging using a modified scintillation camera. J Nucl Med, 1998,39: 2035-2043
  • 2[2]Shao L, Nellemann P, Muehllehner G, et al. Singles-transmission attenuation correctionfor dual head coincidence [ abstract ]. J Nucl Med, 1998,39 (suppl): 37P
  • 3[3]Coleman RE, Laymon CE, Tukington TG. FDG imaging of lung nod ules: a phantom study comparing SPECT, camera based PET, and dedicated PET. Radiology, 1999,210: 823-828
  • 4[4]Kazuki F, Masayoshi S, Koichi N, et al. Attenuation correction for cardiac dual-head γ camera coincidence imaging using segmented myocardial perfusion SPECT. J Nucl Med, 2000,41:919-925
  • 5[5]Laymon CM, Turkington TG, Gilland RE. Transmission scanning on a gamma camera coincidence imaging system[ abstract]. J Nucl Med, 1998,39(suupl) :92P
  • 6[7]Kemp HG, Kronmal RA, Vlielstra RE, et al. Coronary artery surgery study(CASS) paticipants: seven year survival of partients with normal or near normal coronary arteriograms: a CASS registry study. J Am Coll Cardiol, 1986,7:479-485
  • 7[9]Watson DD, Smith WH, Sinusas A J, et al. Myocardial defect detection with Tc-99m methoxyisobutyl isonitrile vs. T1-201. J Nucl Med,1988,29(5): 850-856

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部