期刊文献+

UF-100型尿沉渣分析仪分析老年人尿沉渣变化 被引量:32

Analysis of urine sediment in the elderly by UF-100
下载PDF
导出
摘要 目的 探讨老年人尿沉渣的变化。方法 用UF 10 0型全自动尿沉渣分析仪检测 93例老年人尿沉渣 ,多参数分析尿沉渣的改变。结果 老年人尿红细胞、白细胞、管型、细菌数均升高 ,其中有相当比例明显异常 ;老年女性尿红细胞、白细胞、细菌数异常较男性尤为明显 ;老年人尿液电导率显著降低。结论 老年人肾功能降低 ;尿沉渣异常 ,女性尤为明显。 Objective\ To study the changes of urine sediment in the elderly Methods \ 93 urine samples in the elderly were examined on the automated Flow Cytometer(UF 100),and multiparameter analysis of the changes of urine sediment was performed Results\ Erythrocyte,leukocyte,cast and bacterium counts in the elderly were higher,some of them were obviously abnormal In the elderly women erythrocyte,leukocyte and bacterium in urine were more abnormal than in the elderly men,Conductivity in the elderly was lower significantly Conclusion\ In the elderly,renal function was decreased,urine sediment was abnormal,and more in the elderly women
出处 《临床检验杂志》 CAS CSCD 北大核心 2001年第4期218-219,共2页 Chinese Journal of Clinical Laboratory Science
关键词 尿沉渣分析仪 尿沉渣 老年人 UF-100型 UF 100 urine sediment the elderly
  • 相关文献

参考文献6

二级参考文献6

  • 1金大鸣.UF-100尿沉渣分析仪性能评价[J].中华医学检验杂志,1998,21:190-190.
  • 2丛玉隆 马俊龙 等.雄尿沉渣测定四种方法参考值范围调查[J].中华医学检验杂志,1997,20:229-229.
  • 3兵滕透 熊野和雄 等.流式UF-100分析仪对健康人尿红细胞分析[J].肾脏,1997,75:451-451.
  • 4中华人民共和国卫生部医政司,全国临床检验操作规程(第2版),1997年,162页
  • 5钱桐荪,中华肾脏病杂志,1987年,9卷,3期,125页
  • 6张颖,陈香美,徐启河.流式尿沉渣自动分析仪检测肾小球性血尿的鉴别诊断意义[J].中华内科杂志,1997,36(5):340-340. 被引量:11

共引文献296

同被引文献103

引证文献32

二级引证文献80

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部