主要介绍内螺纹管水压胀塞的设计及可靠性试验、胀塞的拉脱试验、橡胶侧向膨胀力试验及胀头的强度分析及计算。
It is a paper about swelling-plug of rifled tube on water pressure test The designing method,the swelling-plug destructive test,the rubber lateral swelling force test,the swelling-clamp strength analyzing and caculating are discussed