期刊文献+

浅议变压器固体绝缘的化学监督 被引量:1

On chemical supervision of transformers' solid insulation
下载PDF
导出
摘要 常规化学绝缘监督方法是通过气相色谱法等手段来预测变压器内的潜伏性故障 ,但该方法判断变压器固体绝缘老化不准确 ,为此 ,介绍了监测固体绝缘老化的重要化学监测手段———糠醛测试 ,阐明测试的重要意义和方法 。 At present, latent troubles of transformers can be forecasted by means of gas chromatography. It is not accurate, however, to judge if the solid insulating systems in the transformers have been aged. Based on the fact, this paper introduces an important method of solid insulation monitoring furane formaldehyde measurement. At the same time, the authors present how to organically apply the method to chemical prediction in daily work.
机构地区 深圳供电局
出处 《广东电力》 2001年第2期56-58,共3页 Guangdong Electric Power
关键词 变压器 固体绝缘 化学监督 糠醛 气相色谱法 transformer solid insulation chemical supervision furane formaldehyde
  • 相关文献

参考文献1

  • 1温念珠.电力用油实用技术[M].北京:中国水利水电出版社,1997..

同被引文献20

  • 1王志强,柴寿喜,仲晓梅,郭英,王晓燕,魏丽.多元逐步回归分析应用于固化土强度与微结构参数相关性评价[J].岩土力学,2007,28(8):1650-1654. 被引量:20
  • 2Liao Ruijin, Tang Chao, Yang Lijun. Thermal aging micro-scale analysis of power transformer pressboard[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2008,15 ( 5 ) : 1281- 1287.
  • 3Gilbert R, Jalbert J, Duchesne S, et al. Kinetics of the production of chain-end groups and methanol from the depolymerization of cellulose during the ageing of paper/oil systems, part 2: thermally upgraded insulating papers[J]. Cellulose, 2010, 17 (2): 253-269.
  • 4Lundgaard I. E, Hansen W, Linhjell D, et al. Aging of oil-impregnated paper in power transformers[J]. IEEE Transatctions on Power Delivery, 2004, 19(1): 230- 239.
  • 5Emsley A M. Kinetics and mechanisms of degradation of cellulosic insulation in power transformers[J]. Polymer Degradation and Stability, 1994,44(3) : 343-349.
  • 6Calvini P. The influence of levelling off degree of polymerisation on the kinetics of cellulose degradation[J]. Cellulose, 2005, 12 (4) :445-447.
  • 7Calvini P, Gorassini A, Merlani A L. On the kinetics of cellulose degradation: looking beyond the pseudo zero order rate equation[J]. Cellulose, 2008, 15(2): 193 -203.
  • 8Hohlein I, Kachler A J. Aging of cellulose at transformer service temperatures, part 2: influence of moisture and temperature on degree of polymerization and formation of furanic compounds in free-breathing systems[J]. IEEE Electrical Insulation Magazine, 2005, 21(5): 20 -24.
  • 9Saha T K, Purkait P. Understanding the impacts of moisture and thermal ageing on transformer's insulation by dielectric response and molecular weight measurements[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2008,15 (2) :568- 582.
  • 10Kachler A J, Hohlein I. Aging of cellulose at transformer service temperatures, part 1: influence of type of oil and air on the degree of polymerization of pressboard, dissolved gases, and furanic compounds in oil[J]. IEEE Electrical Insulation Magazine, 2005, 21(2): 15- 21.

引证文献1