摘要 热塑丁苯弹性体橡胶 ( SBS)车间 P2 1 5a胶液泵管线运行过程中发生振动 ,尤其是出料结束时管线振动相当严重 ,最大振幅达 979μm。通过管线振动分析计算 ,找出振动原因并提出管线防振改造方案 ,使最大振幅降低到 50 The piping of p215a colloial liquid pump of hot ductility butyl benzene elastomer ruber shop occured vibration during operation.Especially at the end time of effluent,the piping vibration was very serious,the maximum amplitude reached 979μm.By means of piping vibration analysis and calculation,the reason of vibration was found and the transform plan of piping antivibration was proposed,and made the maximum amplitude decrease to less than 50μm.
出处 《石油化工设备技术》 CAS 2001年第3期41-43,共3页 Petrochemical Equipment Technology
关键词 橡胶设备 胶液泵 管线振动 技术改造 加固 防振 Colloidal liquid pump,piping,Vibration,Transform plan
  • 相关文献

参考文献3

  • 1蔡尔辅.石油化工管线设计[M].北京:化学工业出版社,1988..
  • 2袁宏义 等.设备振动诊断技术基础[M].国防工业出版社,1988..
  • 3石成江,刘录,王正,何振岐,周裕银.振动管线计算分析[J].化工机械,1996,23(6):31-35. 被引量:4