期刊文献+

声学定量技术多巴酚丁胺负荷超声心动图检测冠心病心功能变化及意义

Changes and significance of left ventricular function detected in patients with coronary heart diseases by AQI DSE
下载PDF
导出
摘要 目的 :探讨声学定量技术 (AQI)多巴酚丁胺负荷超声心动图 (DSE)检测冠心病 (CHD)心功能变化及临床意义。方法 :应用 AQI- DSE检测 2 9例 CHD患者和 16例正常人的左心功能变化。结果 :AQI- DSE中正常人和 CHD患者的舒张末期容积、收缩末期容积、射血分数、峰值充盈率和峰值充盈时间呈现明显不同的变化趋势。结论 :用AQI方法检测多巴酚丁胺负荷试验能够判断 CHD患者的左心功能状态和心肌缺血的反应。 AIM:To investigate the clinical significance of the left ventricular function in patients with CHD by intelligent acoustic quantification and dobutamine stress echocardiography(AQI DSE). METHODS:The left ventricular function in 29 patients with CHD and 16 normal cases were detected by using of AQI DSE. RESULTS:Various tendencies in end diastolic volume,end systolic volume,ejection fraction and peak filling rate,time to peak filing rate were very different between the both two groups significantly. CONCLUSION:AQI DSE can be used to judge the function of left ventricle and the response of myocardial ischemia in CHD patients.
出处 《心脏杂志》 CAS 2001年第4期274-276,共3页 Chinese Heart Journal
基金 吉林省科委科研课题 (NO.975 4)
关键词 声学定量技术 多巴酚丁胺负荷 冠状动脉疾病 左心室功能 intelligent acoustic quantification dobutanine stress coronary disease ventricular function,left
  • 相关文献

参考文献8

  • 1[1]Antonio V. Detection of ventricular systolic and diastolic abnormalities in patient with coronary artery disease by color kineaia [J]. Clin Cardiol, 1997,20: 927.
  • 2[2]Sebasttian C, Patel JT, Sedaniantz A, et al. Stress echocardiography: A review of the principles and practice[J]. Echocardiography, 1998,15: 669.
  • 3[3]Kohishi T. Radionuclide assessement of left ventricular function during dobutamine infusion patients with coronary artery disease: Comparision with ergoment exercise [J]. Clin Cardiol,1990,3;183.
  • 4[4]Sawada SG,Seger DS,Ryan T,et al. Echocardiographic detection of coronary artery disease during dobutamine infusion[J].Circulation, 1991,83: 1605.
  • 5[5]Cohn JN. A symposium: Advances in congestive heart failure [J]. Am J Cardiol,1988,62:1A.
  • 6[6]Lindower PD,Rath L,Preslar J ,et al. Quantification of left ventricular function with an automated border detection system and comparison with radionuclide ventriculography[J]. Am J Cardiol,1994,73(2): 195.
  • 7[7]Yvorchuk KJ,Davies RA,Chan KL. Measurement of left ventricular ejection fraction by acoustic quantification and comparison with radionuclide angiograph [J]. Am J Cardiol, 1994,74(10):1052.
  • 8[8]Perez JE,Waggoner AD,Barzlai B,et al. On line assessment of ventricular function by automatic boundary detection and ultrasonic backscatter imaging[J]. Am J Cardiol, 1992,19:313.