摘要
介绍了采用变质量热力学原理估算有阀型单级与多级脉管制冷机供气量和输入功的简便方法。该方法物理概念清晰,程序实现容易,理论计算结果与典型的实验结果吻合良好。
It is very important to make the refrigerator match correctly with the compressor used to get a better performance.Based on the thermodynamic analysis,a simple method was proposed to calculate the volume flow per hour and input power for pulse tube refrigerator and gave a good agreement with the typical experimental results.The method was also used to optimize our present two stage double orifice pulse tube refrigerator.
出处
《低温工程》
CAS
CSCD
北大核心
1998年第5期11-15,共5页
Cryogenics
基金
国家自然科学基金