摘要
本文介绍了GIS和SF6断路器的现场检测方法 ,包括机械振动法、检测管检测法和动态电阻检测法 ,分析了每一种检测方法的原理、适用设备。根据试验中发现的问题和经验 ,提出了抗干扰措施。
The field detection techniques of GIS and SF 6 circuit breaker have been introduced, which include several methods of mechanical vibration detection, chemical examination, dynamic contacting resistance detection. The principle, validity and interfer ence immunity of them are presented too.
出处
《高压电器》
CAS
CSCD
北大核心
2001年第3期47-48,共2页
High Voltage Apparatus