摘要
本文研究了用微波消化试样,ICP-AES法同时测定分子筛及担体中的主含量元素Si、Al和杂质元素Fe、Na、Ca、Mg的方法。相对标准偏差:Si、Al<2%,Fe、Na、Ca、Mg≤4%,杂质元素回收率为97%—107%。方法快速,简便,准确,可靠。
The method of simultaneous determination of main content elements (Si and Al) and impurity elements (Fe ,Na ,Ca and Mg)in zeolites and supports has been studied by using ICP AES technique.The samples were pretreated by microwave digestion. The relative standard deviation of the method are <2% for Si and Al and ≤4% for Fe,Na,Ca and Mg ,respectively .The recovery of impurity elements are 97%-107% . This method is rapidly,simply,accurately and reliably.
出处
《光谱实验室》
CAS
CSCD
1998年第6期58-61,共4页
Chinese Journal of Spectroscopy Laboratory