摘要
本文对KBr压片法、KCl压片法以及萨特勒图谱采用的,糊剂法所绘制的三氯异氰尿酸的红外光谱进行了分析、对照。KCl压片法克服了溶剂的影响,简单、直观地体现了物质的精细结构。同时,将三氯异氰尿酸分别与KCl、KBr研磨,和三氯异氰尿酸纯品进行了紫外-可见吸收光谱对照。实验发现,与KBr研磨的三氯异氰尿酸和纯品的吸收峰有差异,而与KCl研磨后的三氯异氰尿酸和纯品一致,说明结构未发生变化。因此,认为KCl压片法是绘制三氯异氰尿酸红外光谱较好的方法。
The paper made acompanision among IR absorption spectra of thrichloro s trlazine 2,4,6(1H,3H,5H) trion which were gotten by KBr,KCl wafer and mull technique,which was used in Sadtler Infrared Spectroscopy Atlats.It was found that KCl wafer eliminated the effect of solvent and directly demonstrated the fine structure of material.The UV VIS absorption spectrum of trichloro s trlazine 2,4,6(1H,3H,5H) trion grinded in KCl was the same with the pure sample,so material had not changed.The IR spectrum of trichloro s trlazine 2,4,6 (1H,3H,5H) trion was satisfactory through KCl wafer.
出处
《光谱实验室》
CAS
CSCD
1998年第2期96-99,共4页
Chinese Journal of Spectroscopy Laboratory
关键词
三氯异氰尿酸
红外光谱
测绘方法
氯化钾压片
消毒剂
强氯精
Trichloro S Trlazinc 2,4,6(1H,3H,5H) Trion,IR Spectrometry,Determination Method,KCl Wafer.