摘要 以NT方法为基础比较了ELISA和FIA方法,共检测84份猴B病毒相关抗体的敏感性,结果ELISA和EIA阳性各50份(59.5%),NT阳性45份(53.6%)。三种方法相符者71份,符合率84.5%。ELISA和FIA均较NT敏感,而且快速,简便,经济,可应用于大批标本的检查。 ELISA and EIA as well as NT in detecting B virus related antibody of 84 Rhesus monkey sera were compared.The results showed that there were 50 positive specimens(59.5%)in ELISA and EIA and 45 positive specimens(53.6%) in NT, 71 specimens of the 84 tested specimens were in the same result by 3 methods, and the concordance among them was 84.5%. ELISA and EIA were more sensitive than NT method,and they are also simple,fast and economical, so they might be used in the examination of a lot of monkey specimens.