期刊文献+

呼吸机管道系统更换与呼吸机相关性肺炎 被引量:115

原文传递
导出
出处 《中华结核和呼吸杂志》 CAS CSCD 北大核心 2001年第8期508-509,共2页 Chinese Journal of Tuberculosis and Respiratory Diseases
  • 相关文献

参考文献10

  • 1WashingtonJA.Respiratorycare:aguidetoclinicalpractice[].Infectiousdisease:aspectsofrespiratorytherapy.1997
  • 2Kollef MH,Shapiro SD,Fraser VJ,et al.Mechanical ventilation with or without 7-day circuit changes: a randomized controlled trial[].Annals of Internal Medicine.1995
  • 3Craven DE,Kunches LM,Kilinsky V,et al.Risk factors for pneumonia and fatality in patients receiving continuous mechanical ventilation[].The American Review of Respiratory Disease.1986
  • 4Cross AS,Roupe B.Role of respiratory assistance devices in endemic nosocomial pneumonia[].The American Journal of Medicine.1981
  • 5Alfredson T,Earl A,Larson R,et al.Effect of extending ventilator circuit changes from 2-3 to every 7 days[].Respiratory Care.1994
  • 6Simmons BP,Wong ES.Guidelines for prevention of nosocomial infection[].American Journal of Infection Control.1983
  • 7Dreyfuss D,Djedaini K,Weber P,et al.Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change[].The American Review of Respiratory Disease.1991
  • 8Dreyfuss D,Djedaini K,Gros I,et al.Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effect on patient colonization and incidence of nosocomial pneumonia[].Am Rev Respir Crit Care Med.1995
  • 9Tablan OC,Anderson LJ,Arden NH,et al.Guideline for prevention of nosocomial pneumonia[].American Journal of Infection Control.1994
  • 10Boher M,Lohse S,Glasby C,et al.Impact of 7 day ventilator tubing changes on nosocomial lower respiratory tract infection[].American Journal of Infection Control.1991

同被引文献792

引证文献115

二级引证文献1261