本文分别从喷头的火灾探测性能和喷水灭火性能出发 ,介绍了自动喷水灭火系统中影响喷头布置的一些相关因素 ,着重讨论了喷头的喷水半径设计参数。
s:On basis of two functions of nozzle,fire detection and sprinkler,some influencing factors related to the arrangement of nozzle in automatic fire-extinguishing sprinkler systems are presented in this paper,among them,design parameter of sprinkler radius is discussed with emphasis.
出处
《福建建筑》
2001年第B10期97-98,共2页
Fujian Architecture & Construction