摘要
论述了消声器在通风空调系统中的作用和衡量消声器好坏的 4个因素 ,阐明在实际工程应用中应根据每项工程的具体情况 ,综合考虑并有所侧重选用消声器。简述了消声器的设置位置和具体安装要求。提出了在通风空调系统中选用消声器的工作步骤并对常用消声器进行了技术分析 ,对各种消声器的适用范围和作用进行了说明。
In this paper, the function of silencer in ventilat ed air-condition sy stem and the four factors to judge the silencer's quality are discussed, in prac tical engineering application, according to each project's concrete situation, integrated consideration and having some emphasis on selecting the silencer are explained. At the same time, the located position and concrete installation demand are simply narrated. There fore, the job step of selecting the silencer in ventilated air-condition system is put forward and the technical analysis to the silencers in common use is car ried out. At last, each silencer's scope of application and function are explain ed.
出处
《山西建筑》
2001年第5期145-146,共2页
Shanxi Architecture
关键词
消声器
消声量
频谱
阻性
通风
空调系统
silencer, amount of noise elimination, spectrum, prevent property, resistant property