本文通过对锅炉运行制度和集中调节方式对水温波动值影响的分析,提 出了合理确定膨胀水箱总容积的方法,并举例说明采用此法可使膨胀水箱总容积减 少32~58%。
According to analysis of that boiler operation and central regulation affect the changing up and down of water temperature, the rational determination of total volume of expansion tank is proposed and one example is given that the total volume of expansion tank can be reduced by 32% to 58% by using this method.
出处
《煤气与热力》
北大核心
1991年第4期46-51,共6页
Gas & Heat