600MW机组锅炉空气预热器密封系统的技术改造 被引量:1

Air preheater airproof system alter ation countermeasure and economic analysis of homemade 600MW unit boiler
下载PDF
导出
摘要 详细分析了元宝山发电厂三分仓回转式空气预热器密封系统漏风率偏大的根本原因,并根据运行中所暴露的问题,以豪顿的VN密封技术为指导,提出密封系统改造的基本方案。改造后漏风率由23%-25%降为7%以下,显著提高了机组运行的可靠性和经济性. The paper analyzes in detail the radi cal reason of high leak rate for air pr eheater airproof system in yuanbaoshan power plant and facing t o the exposed problems in operation,brings forward the radical project o f airproof system alteration directe d by Howden's VN airproof technique.After alteration,the air leak rate d ropped from 23%~25%to 7%below,enhance the economic performance of unit operation is enhanced remarkably.it can be the reference for other enterp rise when alteration.
作者 孟祥东
出处 《沈阳工业大学学报》 EI CAS 2001年第5期409-412,共4页 Journal of Shenyang University of Technology
关键词 空气预热器 密封系统 漏风率 发电厂 600MW机组 锅炉 技术改造 可靠性 经济性 air preheater airproof s ystem air leak rate retrench energ y and reduce wastage
  • 相关文献

参考文献5

二级参考文献3

共引文献32

同被引文献8

  • 1冯俊凯 沈幼庭.锅炉原理与计算[M].北京:科学出版社,1992..
  • 2FRASS A P, OZISIK M N.Heat exchanger design [J] .Wiley, 1963,10:55 - 60.
  • 3BEJAN A, SMITH J L. Heat exchanger for vapor cool conducting supports of cryostats [J]. Advances in Cryogenic Engineering, 1976,21:173- 176.
  • 4MACDUFF E J, CLARK N D. Ljungstrom air preheater design and operation, part Ⅰ : sealing and leakage [J]. Combustion, 1976,47: 7 -11.
  • 5朱明春,刘颖,林庄亮.工程热力学[M].北京:清华大学出版社,1996.
  • 6TEODOR SKIEPKO. A comparison of rotary regenerator theory and experimental results for an air heater for thermal power plant [J]. IEEE Experimental Thermal and Fluid Science,2004,28:257 - 264.
  • 7魏绍青,柳成亮,刘俊.东方锅炉厂LAP10320空预器改进实践与探讨[J].山西电力,2002(3):15-17. 被引量:1
  • 8巩汉强.VN技术在容克式空气预热器密封改造中的应用[J].热能动力工程,2003,18(4):426-428. 被引量:7