摘要
介绍了高温超导输电电缆的交流损耗试验系统 ,电缆交流损耗理论模型以及 1米长高温超导输电电缆的交流损耗试验结果。试验结果表明该电缆在设计电流为工频5 0Hz ,6 0 0Arms时的交流损耗值为 0 .2 2W ,相当于 0 .36 8W
AC losses is one of the critical issues on the development of High T c superconducting transmission cable. In this paper, a kind of electrical ac losses measurement method with lock in amplifier and the ac loss of the one meter long high temperature superconducting transmission cable are presented. The result show that the ac loss of the cable is 0.22 W at operating current 600Arms, 50Hz ( Equal to 0.368W/kA·m), which is much better than designed value 1.0 W/kA·m.
出处
《高技术通讯》
EI
CAS
CSCD
2001年第9期104-106,共3页
Chinese High Technology Letters
基金
973计划资助项目 (G19990 64 60 8)