摘要
针对冶金企业用电设备产生的无功功率含有大量谐波无功分量的特点,合理选择无功补偿方案,提出具有谐波治理功能的TSC就地动态无功功率补偿装置的设计构思。并在安钢小型厂260机组15#机架应用该装置,功率因数提高到0.98以上,谐波得到有效治理。
In accordance with the characteristics of quantity reactive component in reactive component in reactive power created by electric equipment in metallurgical plants. The paper describes a design concept of the TSC local Static var compensator functioning as harmonic suppression through making reasonable select of reactive compensation proposal. The Svc uuit was applied to the No. 15 stand of 260mm rolling in Angang Group facfm increasd over 0.98 and thas the warmonic got to be managed efficiently.
出处
《河南冶金》
2001年第3期11-13,22,共4页
Henan Metallurgy
关键词
TSC
无功补偿
谐波治理
冶金企业
TSC Local static Var compensation harmonic suppression.