期刊文献+

混合工质J-T节流制冷机中换热器特性的试验研究 被引量:1

Experimental Study On The Behavior In The Heat Exchanger Of A Mixed Gas Joule-Thomson Cooler
下载PDF
导出
摘要 文中介绍了对混合工质 J- T节流制冷机中换热器特性实验研究的结果 ,指出多组分混合工质 J- T节流制冷机及其换热器设计过程中 ,混合工质组分配比对整机及换热器换热和流动有重要影响 ,选择组分配比时要统筹考虑混合工质小温差换热段的出现位置及其长度的综合影响。 In this paper, an experiment set has been set up and the experimental results of the mixed gas Joule-Thomson (J-T) cooler and its heat exchanger are provided. These data show that the temperature distribution as well as the pressure distribution in the heat exchanger channels depends to a large degree on the pinch point locations in the process, which is strongly influenced by the mixture composition. Both the pinch part of heat exchanging location should be considered for the optimal design of the heat exchanger as well as for the choice of the mixture composition.
出处 《低温与超导》 CAS CSCD 北大核心 2001年第4期41-45,共5页 Cryogenics and Superconductivity
关键词 混合工质 J-T节流制冷机 换热器 小温差换热段 工作特性 换热性能 Mixed gas, J-T cooler, Heat exchanger, Pinch part of heat exchanging
  • 相关文献

参考文献4

共引文献5

同被引文献14

  • 1龚启兵.锑化铟光伏器件温度特性分析[J].红外与激光技术,1995,24(4):52-55. 被引量:2
  • 2王田刚,陈学康,曹生珠,王瑞,杨建平,吴敢.微型节流制冷器MMR的分析与研究[J].真空与低温,2006,12(3):149-152. 被引量:2
  • 3张祉佑,石秉三.制冷及低温技术:上[M].北京:机械工业出版社,1981:196-197.
  • 4Jepsen,et al.Cryogenic refrigeration system[P].US Pat 3320755,1967-5-23.
  • 5Nicholds,et al.Cryogenic refrigerating apparatus[P].US Pat 3691784,1972-9-19.
  • 6Albagnac,et al.Device for regulating a Joule-Thomson effect refrigerator[P].US Pat 4419867,1983-12-13.
  • 7纪国林.液氮-氖(氢)节流制冷器.低温与超导,1987,15(3):15-19.
  • 8Uwe Hingst.Fast cool-down dual gas spray-cooler for pivoted IR-detectors[C]//SPIE 5074(2003):620-629.
  • 9Hingst.Two stage cooler for cooling an object[P].US Pat 5150579,1992-9-29.
  • 10Patrick Curlier.Cryocoolers Techndogies[C]//SPIE 2552(1995):791-802.