期刊文献+

5-Br-DMPAP直接光度法测定血清铜 被引量:6

Methodology Research of Direct Assay For Cu in Serum With 5-Br-DMPAP
下载PDF
导出
摘要 目的 :建立一种快速、简便、灵敏分光光度法测定血清铜 ;方法 :在表面活性剂 Triton X-1 0 0存在下 ,用 2 - ( 5 -溴 - 2 -吡啶偶氮 ) - 5 -二甲氨基酚 (简称 5 - Br- DMPAP)作显色剂直接光度法测定血清铜 ;结果 :该方法测定血清铜 ,显色络合物最大吸收波长为 5 60 nm,线性范围达 63.0 μ mol· L-1,表观摩尔吸光数为 5 .89× 1 0 4 L·mol-1·cm-1。回收率为 98.8%~1 0 1 .5 % ,变异系数 ( CV) 2 .3% ,与原子吸收分光光度法比较相关良好 ,Y=0 .95 5 X+ 0 .833,r=0 .9663,P>0 .0 5 ,36例健康人血清铜含量为 1 0 .0~ 2 3.6μmol· L-1( x± 2 s) ;结论 :该法血清用量少 ,不必去蛋白 ,具有操作快速、简便、结果灵敏可靠等优点 。 Objective:To establish a simple sensitive and stable method of determination of copper in serum by UV-Spectrophotometry.Methods:For determination of serum copper with 5-Br-DMPAP in the presence of surfactant Triton X-100.Results:The maximum absorption of the complex compound was at 560 nm,The linearity of test was up to 63 0 μmol·L -1 ,The molar absorption coefficient is 5.89×10 4 L·mol -1 ·cm -1 .The recoveries ranged from 98 8% to 101 5%.The CV was 2.3%.Comparing this method (Y)with AAS(X),we obtained the regression equation.Y=0.955X+0.833,r=0.9663,P>0.05,The reference interval (x±2s) was (10.0~23.6) μmol·L -1 (n=36).Conclusions:This method is simple.sensitive,rapid and accurate,and suitable for clinical application
出处 《微量元素与健康研究》 CAS 2001年第3期61-62,共2页 Studies of Trace Elements and Health
基金 浙江省教委科研基金资助 (SQ93 0 0 3 )
关键词 血清诊断 分光光度法 5-Br-DMPAP serum copper spectrophotometry
  • 相关文献

参考文献2

二级参考文献7

  • 1中华人民共和国卫生部医政司,全国临床检验操作规程(第2版),1997年,201页
  • 2曹建明,上海医学检验杂志,1994年,9卷,25页
  • 3曹建明,中华医学检验杂志,1992年,15卷,268页
  • 4朱忠勇,实用医学检验学,1992年,294页
  • 5林其燧,临床化学诊断方法大全,1990年,510页
  • 6范存忠.TritonX-100-5-Br-PADAP分光光度法测定微量铜[J]分析化学,1981(06).
  • 7陈亚华,刘一真.双波长分光光度法同时测定铝合金中铜和铁[J].冶金分析,1990,10(1):17-19. 被引量:13

共引文献31

同被引文献110

引证文献6

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部