期刊文献+

FLAIR与FSE序列在颅脑疾病诊断中的对比应用 被引量:5

Application and Contrast of FLAIR Sequence and FSE Sequence in MRI of the Brain
下载PDF
导出
摘要 目的 探讨脑脊液衰减翻转恢复 (FLAIR)与快速自旋回波 (FSE)在颅脑的应用对比价值。方法  68例颅内病变均用两种序列检查。结果 FLAIR检出病灶 1 3 2枚 ,FSE检出 92枚 ,前者比后者敏感性高。结论 FLAIR优点较多但在有的部位不如FSE ,二种序列应互为补充。 Objective To discuss the value of fluid attenuated inversion recovery (FLAIR) and fast spin echo (FSE) in MRI of the brain. Methods 68 patients were with brain diseases were examined with both FLAIR and FSE sequences. Results FLAIR sequence detected 132 focus of disease, FSE sequence detected 92 focus of disease, the former was more sensitive than the latter. Conclusion FLAIR sequence shows its advantages was more, but for certain areas,it is less sensitive than FSE. FLAIR should become a complementing modality to FSE in brain MRI.
出处 《中国医学影像技术》 CSCD 2001年第10期1023-1024,共2页 Chinese Journal of Medical Imaging Technology
关键词 磁共振 颅脑 脑脊液衰减翻转恢复 快速自旋回波 诊断 Magnetic resonance imaging Brain FLAIR FSE
  • 相关文献

参考文献1

共引文献10

同被引文献26

  • 1李坤成.磁共振成像对脑梗死预后的评价[J].中国CT和MRI杂志,2003,1(1):52-55. 被引量:20
  • 2王雪飚,郭德安.MRI快速FLAIR技术在脑梗死诊断中的应用[J].中国中西医结合影像学杂志,2005,3(2):101-103. 被引量:2
  • 3Lazeron RH, Iamgdon DW, Fllippi M, et al. Neuropsychological impairment in multiple sclerosis patients: the role of (juxta) cortical lesion on FLAIR[J]. Mult Scler, 2000, 6:280-285.
  • 4Kubota T, Yamada K, Kizu O, Hirota T, et al. Relationship between contrast enhancement on fluid-attenuated inversion recovery MR sequences and signal intensity on T2-weighted MR images: visual evaluation of brain tumors [J]. J Magn Reson Imaging, 2005,21:694 - 700.
  • 5Frigon C, Shaw DW, Heckbert SR, et al. Supplemental oxygen causes increased signal intensity in subarachnoid cerebrospinal fluid on brain FLAIR MR imagings obtained in children during general anesthesia [ J]. Radiology, 2004, 233 : 51 - 5.
  • 6Hashemi RH, Bradley WG, Chen DY, et al. Suspected multiple sclerosis: MR imaging with a fllin-sectiou fast FLAIR pulse sequence[J]. Radiology, 1995,196:505 - 510.
  • 7Segawa F, Kishibayashi J, Kamada K, et al. FLAIR images of brain diseases[J]. No To Shinkei, 1994,46:531-538.
  • 8Bradley WG, Scalzo D, Queralt J, et al. Normal pressure h4ydrocephalus: evaluation with cerebrospinal fluid flow measurements at MR imaging[J]. Radiology, 1996,198:523 - 529.
  • 9Hittmair K, Umek W, Schindler EG, et al. Fast FLAIR imaging of the brain using the fast spin-echo and gradient spin-echo techinique [J]. Magn Resort Imaging, 1997,15:405 - 414.
  • 10Hainal JV, De-coene B, Lewis PD, et al. High signal regions in normal white matter shown by heavily T2-weighted CSF nulled IR sequences[J]. J Comput Assist Tomogr,1992,16:506-513.

引证文献5

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部