期刊文献+

Short-term Results of Using Lamellar Corneo-scleral Patch Graft for the Ahmed Glaucoma Valve Implant Surgery

Short-term Results of Using Lamellar Corneo-scleral Patch Graft for the Ahmed Glaucoma Valve Implant Surgery
全文增补中
导出
摘要 Background: Human donor sclera is commonly used in glaucoma implant surgery to cover the external portion of the silicone tube and prevent its erosion through the overlying conjunctiva. Corneo-scleral graft is used in this study as an alternative material for its desirable properties of being transparent, higher in tensile strength, cheap and more readily available. Methods: Eighteen consecutive cases were implanted with the Ahmed glaucoma valve im-plant. The limbal portion of the silicone tube was covered by a comeo-scleral graft obtained from the corneo-scleral rim left over following corneal transplant operation. The effectiveness in protecting the tube from erosion or migration, the transparency of the patch graft and complications encountered after surgery were assessed.Results: At a mean follow-up of 6 months, all tubes were well protected and no complications related to the patch graft were encountered during intra and postoperative period. All comeo-scleral grafts remained transparent and Background: Human donor sclera is commonly used in glaucoma implant surgery to cover the external portion of the silicone tube and prevent its erosion through the overlying conjunctiva. Corneo-scleral graft is used in this study as an alternative material for its desirable properties of being transparent, higher in tensile strength, cheap and more readily available. Methods: Eighteen consecutive cases were implanted with the Ahmed glaucoma valve im-plant. The limbal portion of the silicone tube was covered by a comeo-scleral graft obtained from the corneo-scleral rim left over following corneal transplant operation. The effectiveness in protecting the tube from erosion or migration, the transparency of the patch graft and complications encountered after surgery were assessed. Results: At a mean follow-up of 6 months, all tubes were well protected and no complications related to the patch graft were encountered during intra and postoperative period. All comeo-scleral grafts remained transparent and healthy at the latest follow-up. Conclusion: Lamellar corneo-scleral tissue from residual comeal transplant material, with its many unique properties and advantages, appears to be a cheap, easily available and effective patch graft material for glaucoma implant surgery. Further explorations and studies on this material are recommended. Eye Science 1997; 13 : 109 - 112.
出处 《眼科学报》 1997年第3期109-112,共4页 Eye Science
关键词 短期效果 角膜 巩膜 移植 青光眼 外科手术 corneal sclera, patch graft, glaucoma, implant surgery
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部