期刊文献+

Comparative Study of Hyperacuity and Retinometer Tests for the Evaluation of Vision in Patients with Advanced Cataract

Comparative Study of Hyperacuity and Retinometer Tests for the Evaluation of Vision in Patients with Advanced Cataract
全文增补中
导出
摘要 Objective: To investigates the clinical application value of hyperacuity test for evaluating vision through dense cataracts.Methods: Ten normal subjects (20 years) were tested both with Bailey-Lovie type chart and three points vernier acuity test (one of the hyperacuity test) ; and retinometer test were performed preoperatively and postoperatively in 30 patients (31 eyes) with senile cataract. These patients' lens opacity was classified with LOGS III system.Results: The correlation of vernier acuity and visual acuity of normal subjects is significant. The result of difference compression of pre-surgical and post-surgical vernier acuity of 30 cataract patients is not significant. The correlation of retinometer findings with post-surgical visual acuity shows not statistically significant. Our result shows that there is good correlation between vernier acuity and post-surgical visual acuity.Conclusion: It appears that hyperacuity is a good test for foveal function behind dense cataract and other ocular Objective: To investigates the clinical application value of hyperacuity test for evaluating vision through dense cataracts. Methods: Ten normal subjects (20 years) were tested both with Bailey-Lovie type chart and three points vernier acuity test (one of the hyperacuity test) ; and retinometer test were performed preoperatively and postoperatively in 30 patients (31 eyes) with senile cataract. These patients' lens opacity was classified with LOGS III system. Results: The correlation of vernier acuity and visual acuity of normal subjects is significant. The result of difference compression of pre-surgical and post-surgical vernier acuity of 30 cataract patients is not significant. The correlation of retinometer findings with post-surgical visual acuity shows not statistically significant. Our result shows that there is good correlation between vernier acuity and post-surgical visual acuity. Conclusion: It appears that hyperacuity is a good test for foveal function behind dense cataract and other ocular opacities. Eye Science 1997; 13: 164 - 167.
机构地区 University of Waterloo
出处 《眼科学报》 1997年第3期164-166,161,共4页 Eye Science
关键词 听觉过敏 视网膜病 白内障 视力评估 hyperacuity, retinometer, cataract
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部