对引进型 30 0 MW汽轮机再热主汽门的轴封结构和漏汽的原因进行了叙述、分析 ,提出了轴封漏汽的解决措施 ,并取得了较好的效果 。
In this article,the steam leakage reason of reheat throttle-stop valve gland seal for the 300MW introduced steam turbine was analyzed and its construction was narrated.The measure to solve this problem was proposed and a better result was obtained.It is worthy to spread th e measure.
出处
《湖北电力》
2001年第3期20-22,共3页
Hubei Electric Power
关键词
再热主汽门
轴封
漏汽
汽轮机
reheat throttle-stop valve
gland seal
steam leakage
measure