摘要
利用振动测试系统测试电力变压器空载状况下各相振动情况 ,以此研究空载时变压器器身的振动特性。该法与电力系统没有直接的电气连接 ,故效果良好 ,研究表明变压器器身振动基频为 10 0 Hz,10 0 0 Hz后谐波衰减至
The vibration method using on line monitor of the power transformer has no direct connection with the power system, it is a recommended method that should be studied deeply. In this paper, the vibration signal of power transformers under no load condition was measured, the vibration characteristic was described.
出处
《高电压技术》
EI
CAS
CSCD
北大核心
2001年第5期47-48,共2页
High Voltage Engineering
基金
西安交通大学博士论文基金资助项目 ( DFXJU2 0 0 0- 4)