根据小水电丰富地区对同期并列的实际需要 ,在概述了同期并列的种类及综合自动化变电站同期并列的方式和特点的基础上 ,提出了 1 1 0kV变电站系统配置分散同期并列的设计思想 ,并就分散同期的参数设定进行了较详细的描述。该设计思想已在 1个采用CSC 2 0 0 0变电站自动化系统的 1 1 0kV变电站中得到应用 。
According to the actual requirement of the area with abounding small hydropower,the design concept of collocating scattered synchro juxtaposition within 110 kV integrated automation substation system is proposed.The types,manner and idiosyncrasy of synchro juxtaposition in integrated automation substation are summarized,and its parameter setting is detailed.It has been applied to a 110 kV substation with CSC2000 integrated automation system and has some popularization and application value.