摘要 该烤房解决了我国多数烟区几十年来使用的“火龙”式烤房的几个突出问题。采用平板散热、立式火炉、型煤燃烧等措施后,使供热系统效率提高20%,排烟温度降低100℃,脱水耗热量降到4300kJ/kg,为国内提供了一个耗能水平低的新型炕种。 The new flue-cured tobacco-room solves some outstanding problems in the tobacco production regions of China where the traditional ' Hue Lung ' flue cured tobacco-rooms have been used for several decades. Adopting advanced technologies, such as flat radiator, vertical stove and briquette as fucl, the heat efficiency of the system can be increased by 20%, the smoke temperature can be reduced by 100t and the heat consumption for dehydration can be dropped to 4389 kJ / kg. So it is one of the best flue-cured tobacco device with lower energy consumption for the Chinese users.