摘要 本文通过现场水质测试 ,并采用数学模型 ,对某抽水蓄能电站上、下池水质的相互影响进行了研究 .预测采用的数学模型部分得到了现场实测结果的验证 .预测结果表明 ,电站运行对上、下池局部区域的水质有一定影响 ,但影响的范围和程度都十分有限 .本文采用的数学模型及提供的实测数据对类似问题具有借鉴和参考价值 . The interactive effect of water quality in upper and lower pools of a pumped storage power plant is studied through field measurement and numerical approach. The mathematical models adopted are partly verified by measured data. The predicted results show that the operation of power plant may influence the water in local area of the pools. However, both the area and degree being affected are limited in a small range.
出处 《水利学报》 EI CSCD 北大核心 2001年第10期67-71,共5页 Journal of Hydraulic Engineering
关键词 抽水蓄能电站 水质 数学模型 测试 pumped storage power plant upper and lower pools water quality interaction mathematical model field measurement