期刊文献+

火焰原子吸收光谱法测定缓蚀剂中铁

Measurement of Iron in Corrosion Inhibitor Using Flame Atomic Ab sorption Spectrometry
下载PDF
导出
摘要 研究了合成氨装置中含缓蚀剂砜—胺脱碳溶液中微量金属元素铁的火焰原子吸收分光光度法的测定,用钙做抑制剂克服硅、钾、钠和钒的干扰,盐酸酸化加热处理试样,消除不同价态铁的影响,方法简便、省时,具有良好的精密度和准确度,回收率为92%~104%,平均相对标准偏差小于5%。 it researches flame atomic absorption spectrometry measurement of microelement of iron contained in sulfone-amine decar-bonizing solution corrosion inhibitor of synthetic ammonia plant,overcoming influence of silicon,potassium,sodium and vanadium by us-ing calcium as depressant,and treating sample by hydrochloric acid acidification heating,to illuminate influence of different iron valence,the method is handy,time-saving and has quite good precision and accuracy,with recycle rate of92%~104%,and average relative stan-dard deviation of less than5%.
作者 于静 王伟众
出处 《黑龙江石油化工》 2001年第4期41-43,共3页 Heilongjiang Petrochemical Technology
关键词 火焰原子吸收光谱法 缓蚀剂 测定 合成氨 净化 flame atomic absorption spectrum corrosion inhibitor iron
  • 相关文献

参考文献2

  • 1张桂广.-[J].光谱学与光谱分析,2000,20(1):354-354.
  • 2周复元(译).-[J].分析化学译刊,1986,19(3):160-160.