本文推导了双能γ射线穿透法测量煤灰分的公式,为数据处理提供了数学依据。在较宽的灰分范围内,实验测量误差好于±1%。
This paper discusses the dependence of gamma-ray interactions with matter on atomic number. A formula of measuring the ash content of the coal by dual energy gamma-ray transmission techniques has been derived to provide the mathematical basis for data processing. The measurement error is less than±1% in the rather wide ash range. Problems encounterred probably in practical application are discussed.
出处
《核电子学与探测技术》
CAS
CSCD
北大核心
1989年第3期146-151,共6页
Nuclear Electronics & Detection Technology
关键词
煤
灰分
Γ射线
质量吸收
原子数
Dual energy gamma-ray transmission techniques, Mass absorption coefficient, Atomic number, Ash, Mass thickness