本文应用故障树分析方法,计算了秦山核电厂自备应急电源系统的瞬时和稳态无效度,并对秦山核电厂自备应急电源系统的设计进行了评价。
In this paper,the transient and steady-state unavailability of the self-emergency power system for Qinshan nuclear power plant with fault tree analysismethod.The design of the self-emergency power system is also evaluated.