根据现场实测数据 ,确定了南钢 10 0 t高阻抗电弧炉的非线性电抗模型。着重讨论了建立电弧炉电抗模型的原则。
Based on production data of 100 t high impedance EAF at Nanjing Iron and Steel Group Co.,Ltd ,in this paper,the principle,method of establishing reactance calculation model for EAF and the target,significance of establishing proper power supply system are discussed
出处
《钢铁》
CAS
CSCD
北大核心
2001年第10期20-22,38,共4页
Iron and Steel